Specs

PoE4 PoE Ports
LEDsW/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
Weight460 g (1 lb)
Buttons(1) Factory reset
MountingDIN-rail (Included)
Store SKUUA-Hub-Gate
Dimensions175 x 126 x 26 mm (6.9 x 5 x 1")
Power MethodPoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
AUX Terminals1 AUX terminal
Digital InputGate exit request, gate position, side door exit request, side door position, emergency
PoE Interface(1) PoE++ input, 50V DC, 1A (4) PoE+ outputs, 50V DC, 30W per port (Max 55W aggregated)
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Lock Terminals1 Lock terminal
NDAA CompliantTrue
Input Terminals(1) Gate exit request (1) Gate position (1) Side door exit request (1) Side door position (1) Emergency
Supported Doors1 gate, 1 side door
Dry Output Relay(2) Operator: rated 30V DC, up to 1A (1) Aux: rated 30V DC, up to 1A
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Additional Inputs5 Additional Inputs
Enclosure MaterialPolycarbonate
Maximum User Count6,000
Networking Interface(5) 10/100/1000 Base-T
Powered Output RelaySide door lock: 12V DC, up to 1A
Software InformationThe software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Indoor and Outdoor UseIndoor only: device itself Outdoor: with waterproof junction box
Management ApplicationAccess
Max. Power Consumption22W (Without PoE output) 60W (With PoE output)
CAN/ULC-60839-11-1 GradeGrade assignment: I
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
Ambient Operating Humidity5 to 90% noncondensing
Ambient Operating Temperature-30 to 60° C (-22 to 140° F)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
Document number, and issue date and/or revision levelUA-Hub-Gate, V01