Specs

PoE2 PoE Ports
LEDsW/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
Weight190 g (6.7 oz)
Buttons(1) Factory reset (1) Dry/Wet switch
MountingDIN-rail (Included)
Store SKUUA-Hub-Door-Mini
Dimensions113 x 66 x 27.6 mm (4.4 x 2.6 x 1.1")
Power MethodPoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
PoE Interface(1) PoE++ input, 50V DC, 1A (2) PoE+ outputs, 50V DC, 30W per port (Max 45W aggregated)
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Lock Terminals1 Lock Terminal
NDAA CompliantTrue
Input Terminals(1) Door exit request (1) Door position
Supported Doors1
Dry Output Relay30V DC, 1A
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Wet Output Relay12V DC, 1A
Additional Inputs2 Additional Inputs
Enclosure MaterialPolycarbonate, metal
Maximum User Count3,000
Networking Interface(3) GbE RJ45 ports
Software InformationThe software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
Indoor and Outdoor UseIndoor only
Management ApplicationAccess
Max. Power Consumption19W (Without PoE output) 50W (With PoE output)
CAN/ULC-60839-11-1 GradeGrade assignment: I
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
Ambient Operating Humidity5 to 90% noncondensing
Ambient Operating Temperature0 to 40° C (32 to 104° F)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Document number, and issue date and/or revision levelUA-Hub-Door-Mini, V01