How to program a wireless zone on a VISTA-20P

Updated Source: K5305-1PRV9 Rev BSource: K5305-1PRV9 Rev BAsked 8 times

Program a VISTA-20P wireless zone from an alpha keypad in *56 Zone Programming mode: pick a zone from 09-48, set the zone type, partition and report code, choose input type 3 (supervised RF), then enroll the transmitter's serial and loop number by faulting it or typing the 7-digit serial from its label.

Steps

  1. From an alpha keypad connected to the panel, enter programming mode: type the installer code 4112 (factory default), then 8 0 0. (VISTA-20P/15P Programming Guide, p. 5)
  2. Press *56 to open Zone Programming menu mode, the mode that sets zone attributes and enrolls 5800 RF transmitter serial numbers. (VISTA-20P/15P Programming Guide, p. 5)(VISTA-20P/15P Programming Guide, p. 23)
  3. At SET TO CONFIRM? enter 1 (Yes) so the panel asks you to confirm each transmitter after you enter its serial and loop number, then press [*]. (VISTA-20P/15P Programming Guide, p. 23)
  4. At Enter Zn Num. type a wireless zone number from 09-48 (zone 10 in the manual's example) and press [*]. The summary screen opens. (VISTA-20P/15P Programming Guide, p. 23)
  5. Enter the zone type, for example 03 for Perimeter, and press [*]. Entering 00 prompts to delete the zone. (VISTA-20P/15P Programming Guide, p. 23)
  6. Enter the partition: 1 or 2, or 3 for the common partition, and press [*]. (VISTA-20P/15P Programming Guide, p. 23)
  7. Enter the report code as two 2-digit entries. For report code 10, enter 01 then 00; enter 00 to disable reporting. Press [*]. (VISTA-20P/15P Programming Guide, p. 24)
  8. At INPUT TYPE enter 3 for a supervised RF transmitter (4 = UR unsupervised RF, 5 = button-type RF), then press [*]. (VISTA-20P/15P Programming Guide, p. 24)
  9. At INPUT S/N: L enroll the transmitter: send two open/close sequences from it, or type the 7-digit serial number from its label, press [*] and enter the loop number. (VISTA-20P/15P Programming Guide, p. 25)
  10. Press [*] so the panel checks for a duplicate serial and loop number, then press [*] again to reach the confirmation screen. (VISTA-20P/15P Programming Guide, p. 25)
  11. At XMIT TO CONFIRM activate the loop input or button for this zone. A match beeps the keypad 3 times and shows the summary with an s after the loop number. (VISTA-20P/15P Programming Guide, p. 25)
  12. At PROGRAM ALPHA? enter 0 to skip descriptors (or 1 to add them through *82). At ENTER ZN NUM. enter the next zone, or 00 to quit. (VISTA-20P/15P Programming Guide, p. 25)
  13. Leave programming with *99, which allows re-entry with installer code + 8 0 0. Avoid *98 unless you want to lock out that re-entry. (VISTA-20P/15P Programming Guide, p. 5)
  14. Check signal strength from each transmitter location with Go/No Go Test: installer code + [#] + 4, fault each transmitter and listen for 3 beeps. Exit with the user code + 1 (OFF). (VISTA-20P/15P Quick Installation Guide, p. 1)

Worked example

Enrolling one supervised door contact on zone 10, using the values from the programming guide's example screens (p. 23-25):

  • 4112 8 0 0, then *56, then 1 [*] at SET TO CONFIRM?
  • Zone 10 [*] · zone type 03 Perimeter · partition 1 · report code 01 00 · input type 3 RF
  • Serial A022-4064, loop 1: fault the contact twice, press [*] [*], fault it again at XMIT TO CONFIRM
  • Summary screen reads 10 03 10 RF: 1s (zone 10, type 03, report code 10, RF input, loop 1, serial enrolled)
  • 0 at PROGRAM ALPHA?, 00 to quit, *99 to exit

Specs & limits

Wireless zone numbersVISTA-20P: 09-48 (40 transmitter zones). VISTA-15P: 09-34 (26 transmitter zones). (VISTA-20P/15P Programming Guide, p. 23)(VISTA-20P/15P Quick Installation Guide, p. 2)
RF button zonesVISTA-20P: 49-64. VISTA-15P: 49-56. (VISTA-20P/15P Programming Guide, p. 23)
Receiver capacity5881L / 5882L: up to 8 RF zones. 5881M / 5882M / 6150RF: up to 16 RF zones. 5881H / 5882H / 5883 / 6160RF: up to the system maximum. (VISTA-20P/15P Quick Installation Guide, p. 1)
Receiver addressSet the RF receiver to address 00 with its DIP switches. (VISTA-20P/15P Quick Installation Guide, p. 1)
Input type codes3 = RF (supervised), 4 = UR (unsupervised RF), 5 = BR (button-type RF). (VISTA-20P/15P Programming Guide, p. 24)
Default installer code4112; programming mode is installer code + 8 0 0. (VISTA-20P/15P Programming Guide, p. 5)
Wireless keypadsSet field *24 RF House ID Code when using wireless keypads. (VISTA-20P/15P Quick Installation Guide, p. 1)
RF supervision (V20PCN, ULC)Three hours for fire zones (zone types 9 and 16), 12 hours for all other zone types. (VISTA-20P/15P Quick Installation Guide, p. 2)
Battery12V, 4AH sealed battery shown on the quick install wiring diagram. (VISTA-20P/15P Quick Installation Guide, p. 2)
FirmwareThe programming guide applies to microprocessor version 9.12 or higher. (VISTA-20P/15P Programming Guide, p. 5)

What you need

Common mistakes

Applies to

VISTA-20P · microprocessor 9.12 or higherVISTA-20PSIAVISTA-15P · zones 09-34

Also asked as: “how to program wireless zone into vista 20p”

Sources

  1. VISTA-20P/15P Programming Guide, p. 5 (K5305-1PRV9 Rev B)
  2. VISTA-20P/15P Programming Guide, p. 23 (K5305-1PRV9 Rev B)
  3. VISTA-20P/15P Programming Guide, p. 24 (K5305-1PRV9 Rev B)
  4. VISTA-20P/15P Programming Guide, p. 25 (K5305-1PRV9 Rev B)
  5. VISTA-20P/15P Quick Installation Guide, p. 1 (K5305-1QGV3 Rev A)
  6. VISTA-20P/15P Quick Installation Guide, p. 2 (K5305-1QGV3 Rev A)
  7. VISTA-20P/15P Programming Guide, p. 27 (K5305-1PRV9 Rev B)
Was this right?