LV Handbook › Parts › HID › Access › RP40
Photo coming soon
1 / 1

HID RP40 End of life

HID

Direct replacement: HID Signo 40

Sign in to use the replacement in saved layouts and lists.

iCLASS SE / multiCLASS SE 13.56 MHz contactless readers

Documents & links

Factory datasheet Factory datasheet
Install guide Install guide (PLT-01579 Rev A.6)
Manufacturer product page Manufacturer product page
Last verified Oct 17, 2026 · PLT-01579 Rev A.6 ·
Report broken link

Reviews

No reviews yet.

Where to Buy

Guides

Specs

Input voltage 5-16 VDC (12 VDC for RS-485)
Standby avg 65 mA (920N) · 85 mA (920P) · 120 mA (920L)
Max avg 95 mA (920N) · 100 mA (920P) · 145 mA (920L)
Peak 200 mA
OSDP module +40 mA
Supply Listed access control / burglary power-limited supply (UL)
Wiegand cable 500 ft of 22 AWG, or 300 ft of 24 AWG. 5-9 conductors.
OSDP cable 4000 ft bus, 24 AWG, 1640 ft between nodes. 4-conductor twisted pair, overall shield, UL approved (Belden 3107A or equiv) 120 ohm +/-2 ohm across bus ends if >200 ft (61 m) or EMI
Operating temp -30F to 150F (-35C to 65C); BT config -13F to 150F
Outdoor Yes
IP rating Not in guide
Read range Not in guide
Dimensions Not in guide
Mounting Backplate to junction box or wall; Imperial 0.138-32 x 0.375 in screws, metric M3.5 x 12 mm, wall 0.138-20 x 1.5 in; security screw 0.138-32 x 0.375 in (HID tool 04-0001-03)
UL 294 Access control line security I, destructive attack I, endurance IV, standby power I
Config Order code x3=R adds RS-485/OSDP; behaviour changed via purchasable config cards (audio/visual, CSN, keypad output). Guide does not describe a DIP/jumper selector.
Status End of life

Wiring Wiegand

Wiegand OSDP

LeadPinFunctionController (generic)
Red P1-4 +VDC power VO / +12V
Black P1-3 Ground (RTN) GND
Green P2-3 Wiegand Data 0 / Clock-and-Data Data D0 / DAT
White P2-4 Wiegand Data 1 / Clock D1 / CLK
Orange P1-2 LED input (green) LED
Yellow P1-1 Beeper input BZR
Brown P1-6 LED input (red)
Optional; most single-LED-line reader ports leave capped
Capped
Blue P1-7 Hold input (buffer card or disable read, per config)
Optional
Capped
Drain P1-5 Unused (per guide)
Guide lists as unused; shield bonding practice not specified by guide
Capped
Violet P2-5 Open collector output / tamper (syncs to ground when active, default)
OC output: 5 VDC, sink 40 mA / source 1 mA, host mode only
Optional aux input
Red/Green P2-7 GPIO1 / OSDP RS-485 A (FDX/HDX) Capped
Tan P2-6 GPIO2 / OSDP RS-485 B (FDX/HDX) Capped
Pink P2-2 GPIO3 (RS-485 FDX Z)
Full-duplex only
Capped
Gray P2-1 GPIO4 (RS-485 FDX Y)
Full-duplex only
Capped

Controller terminal names are HireLV generic Mercury-style reader-port labels, not from the HID guide. Map per actual controller.

Controller terminal names are HireLV generic Mercury-style reader-port labels, not from the HID guide. Map per actual controller.

Tech tips

A published tip earns contributor points. Submitting does not.

No published tips yet.

Sign in to submit a tip.

Discussions 0 tagged

No discussions tagged to this part yet.

Start a discussion about this part

Training for this product

All HID training in the Training directory →