HID R15 · 1 of 1 · Image: HID
iCLASS SE / multiCLASS SE 13.56 MHz contactless readers
| Factory datasheet | Factory datasheet |
| Install guide | Install guide (PLT-01579 Rev A.6) |
| Manufacturer product page | Manufacturer product page |
No reviews yet.
Distribution
Market
| Input voltage | 5-16 VDC (12 VDC for RS-485) |
|---|---|
| Standby avg | 60 mA (910N) · 75 mA (910P) · 110 mA (910L) |
| Max avg | 95 mA (910N) · 100 mA (910P) · 135 mA (910L) |
| Peak | 200 mA |
| OSDP module | +40 mA |
| Supply | Listed access control / burglary power-limited supply (UL) |
| Wiegand cable | 500 ft of 22 AWG, or 300 ft of 24 AWG. 5-9 conductors. |
| OSDP cable | 4000 ft bus, 24 AWG, 1640 ft between nodes. 4-conductor twisted pair, overall shield, UL approved (Belden 3107A or equiv) 120 ohm +/-2 ohm across bus ends if >200 ft (61 m) or EMI |
| Operating temp | -30F to 150F (-35C to 65C); BT config -13F to 150F |
| Outdoor | Yes |
| IP rating | Not in guide |
| Read range | Not in guide |
| Dimensions | Not in guide |
| Mounting | Backplate to junction box or wall; Imperial 0.138-32 x 0.375 in screws, metric M3.5 x 12 mm, wall 0.138-20 x 1.5 in; security screw 0.138-32 x 0.375 in (HID tool 04-0001-03) |
| UL 294 | Access control line security I, destructive attack I, endurance IV, standby power I |
| Config | Order code x3=R adds RS-485/OSDP; behaviour changed via purchasable config cards (audio/visual, CSN, keypad output). Guide does not describe a DIP/jumper selector. |
| Lead | Pin | Function | Controller (generic) |
|---|---|---|---|
| Red | P1-4 | +VDC power | VO / +12V |
| Black | P1-3 | Ground (RTN) | GND |
| Green | P2-3 | Wiegand Data 0 / Clock-and-Data Data | D0 / DAT |
| White | P2-4 | Wiegand Data 1 / Clock | D1 / CLK |
| Orange | P1-2 | LED input (green) | LED |
| Yellow | P1-1 | Beeper input | BZR |
| Brown | P1-6 | LED input (red) Optional; most single-LED-line reader ports leave capped |
Capped |
| Blue | P1-7 | Hold input (buffer card or disable read, per config) Optional |
Capped |
| Drain | P1-5 | Unused (per guide) Guide lists as unused; shield bonding practice not specified by guide |
Capped |
| Violet | P2-5 | Open collector output / tamper (syncs to ground when active, default) OC output: 5 VDC, sink 40 mA / source 1 mA, host mode only |
Optional aux input |
| Red/Green | P2-7 | GPIO1 / OSDP RS-485 A (FDX/HDX) | Capped |
| Tan | P2-6 | GPIO2 / OSDP RS-485 B (FDX/HDX) | Capped |
| Pink | P2-2 | GPIO3 (RS-485 FDX Z) Full-duplex only |
Capped |
| Gray | P2-1 | GPIO4 (RS-485 FDX Y) Full-duplex only |
Capped |
Controller terminal names are HireLV generic Mercury-style reader-port labels, not from the HID guide. Map per actual controller.