Altronix EFLOW104NA8V · 1 of 1 · Image: Altronix
Key specs
| Input | Input 220VAC 50/60Hz, 2.7A.; a) One (1) common power input for ACM8 and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to |
|---|---|
| Output | 24VDC outputs @ 10A supply current.; Eight (8) independently trigger controlled outputs.; a) Eight (8) Fail-Safe filtered power outputs.; b) Eight (8) Fail-Secure filtered power outputs.; c) Eight (8) form "C" relay outputs (rated @ 5A/24VDC or VAC).; d) Any combination of the above.; Eight (8) unsw |
| Electrical | Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.; 24VDC: 123 BTU/Hr. |
| Supervision | AC fail supervision (form "C" contacts).; Battery fail & presence supervision (form "C" contacts).; Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% (depending on the power supply). Prevents deep battery discharge. |
| Temperature | Operating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F). |
| Input options | a) Eight (8) normally open (NO) inputs.; b) Eight (8) open collector inputs.; c) Any combination of the above. |
| Output options | a) Eight (8) Fail-Safe filtered power outputs.; b) Eight (8) Fail-Secure filtered power outputs.; c) Eight (8) form "C" relay outputs (rated @ 5A/24VDC or VAC).; d) Any combination of the above. |
| Battery Charging | Built-in charger for sealed lead acid or gel type batteries.; Maximum charge current: 1.54A.; Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.; Zero voltage drop when unit switches over to battery backup (AC failure co |
| BTU/Hr. (approx.) | 24VDC: 123 BTU/Hr. |
| Visual Indicators | Red LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.; AC input and DC output LED indicators. |
| Fire Alarm Disconnect | Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.; a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.; Alarm output relay indicates that FACP input is triggered ( |
| eFlow Power Supply Board | AC input and DC output LED indicators. |
| Power supply input options | a) One (1) common power input for ACM8 and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A tota |
| ACM8 Access Power Controller | Red LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered. |
| Fire Alarm disconnect input options | a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit. |
Where to buy
No retail prices for EFLOW104NA8V yet.Check retailers
Documents
Guides that use this part
No guides tag this part yet.Browse guides
Contractors certified on Altronix
Find Contractors who list a Altronix certification.Find Contractors
Q&A and reviews
Discussions 0 tagged
No discussions tagged to this part yet.
Reviews
No reviews yet.
Max 4. Remove one.
Compare now