LV Handbook › Parts › Altronix › Power › EFLOW104NA8V
Altronix EFLOW104NA8V
1 / 1
+ Add field photo
ALAltronix · Power

EFLOW104NA8V

Power

Add to list

Key specs

InputInput 220VAC 50/60Hz, 2.7A.; a) One (1) common power input for ACM8 and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to
Output24VDC outputs @ 10A supply current.; Eight (8) independently trigger controlled outputs.; a) Eight (8) Fail-Safe filtered power outputs.; b) Eight (8) Fail-Secure filtered power outputs.; c) Eight (8) form "C" relay outputs (rated @ 5A/24VDC or VAC).; d) Any combination of the above.; Eight (8) unsw
ElectricalOperating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).; Relative Humidity: 85% +/- 5%.; 24VDC: 123 BTU/Hr.
SupervisionAC fail supervision (form "C" contacts).; Battery fail & presence supervision (form "C" contacts).; Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% (depending on the power supply). Prevents deep battery discharge.
TemperatureOperating: 0° C to 49° C (32° F to 120° F).; Storage: - 20° C to 70° C ( - 4° F to 158° F).
Input optionsa) Eight (8) normally open (NO) inputs.; b) Eight (8) open collector inputs.; c) Any combination of the above.
Output optionsa) Eight (8) Fail-Safe filtered power outputs.; b) Eight (8) Fail-Secure filtered power outputs.; c) Eight (8) form "C" relay outputs (rated @ 5A/24VDC or VAC).; d) Any combination of the above.
Battery ChargingBuilt-in charger for sealed lead acid or gel type batteries.; Maximum charge current: 1.54A.; Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption.; Zero voltage drop when unit switches over to battery backup (AC failure co
BTU/Hr. (approx.)24VDC: 123 BTU/Hr.
Visual IndicatorsRed LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.; AC input and DC output LED indicators.
Fire Alarm DisconnectFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.; a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.; Alarm output relay indicates that FACP input is triggered (
eFlow Power Supply BoardAC input and DC output LED indicators.
Power supply input optionsa) One (1) common power input for ACM8 and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8 and one (1) for lock accessory power, (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A tota
ACM8 Access Power ControllerRed LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.
Fire Alarm disconnect input optionsa) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.

Where to buy

No retail prices for EFLOW104NA8V yet.Check retailers

Documents

Guides that use this part

No guides tag this part yet.Browse guides

Contractors certified on Altronix

Find Contractors who list a Altronix certification.Find Contractors

Q&A and reviews

Discussions 0 tagged

No discussions tagged to this part yet.

Start a discussion about this part