Altronix AL1024ULACMCBJ · 1 of 1 · Image: Altronix
ALAltronix · Power
AL1024ULACMCBJ
Access Power Controller w/ Power Supply/Charger, 8 PTC Class 2 Relay Outputs, 24VDC @ 10A, FAI, 115VAC, BC600G Enclosure
Key specs
| Input | Input 115VAC 60Hz rated @ 4.2A.; a) One (1) common power input for ACM8CB and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8CB and one (1) for lock accessory power (external power supply is required). Current is determined by the power supply connected, |
|---|---|
| Output | 24VDC @ 10A supply current.; Class 2 Rated PTC protected power limited auto-resettable outputs.; Eight (8) independently controlled outputs.; Eight (8) Fail-Safe and/or Fail-Secure power outputs.; Eight (8) auxiliary power outputs (unswitched). |
| Features | Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.; a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.; Alarm output relay indicates that FACP input is triggered ( |
| Supervision | AC fail supervision (form "C" contacts).; Notification trigger is selectable for 30 seconds (factory set) or 6 hours.; Low battery and battery presence supervision (form "C" contact). |
| Temperature | Operating: 0ºC to 49ºC (32ºF to 120ºF).; Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).; Relative Humidity: 85% +/- 5%.; BTU/Hr. (approx.): 123 BTU/Hr. |
| Input options | a) Eight (8) normally open (NO) inputs.; b) Eight (8) open collector inputs.; c) Any combination of the above. |
| Output options | Eight (8) Fail-Safe and/or Fail-Secure power outputs.; Eight (8) auxiliary power outputs (unswitched). |
| Output ratings | PTCs are rated @ 2.5A.; Filtered and electronically regulated outputs (built-in power supply).; ACM8CB board main fuse is rated at 10A. |
| Battery Charging | Built-in charger for sealed lead acid or gel type batteries.; Automatic switch over to stand-by battery when AC fails.; Zero voltage drop when unit switches over to battery backup (AC failure condition).; AC fail supervision (form "C" contact).; Battery fail and battery presence supervision (form "C |
| Visual Indicators | Red LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.; AC input and DC output LED indicators. |
| Power supply input options | a) One (1) common power input for ACM8CB and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8CB and one (1) for lock accessory power (external power supply is required). Current is determined by the power supply connected, not to exceed a maximum of 10A t |
| Fire Alarm disconnect input options | a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit. |
Where to buy
No retail prices for AL1024ULACMCBJ yet.Check retailers
Documents
Guides that use this part
No guides tag this part yet.Browse guides
Contractors certified on Altronix
Find Contractors who list a Altronix certification.Find Contractors
Q&A and reviews
Discussions 0 tagged
No discussions tagged to this part yet.
Reviews
No reviews yet.
Max 4. Remove one.
Compare now