ALAltronix · Power

AL1024ULACM

Access Power Controller w/ Power Supply/Charger, 8 Fused Relay Outputs, 24VDC @ 10A, FAI, 115VAC, BC400 Enclosure

Add to list

Key specs

InputInput 115VAC 60Hz rated @ 4.2A.; a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power suppl
Output24VDC @ 10A supply current.; Eight (8) independently controlled outputs.; a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.; Eight (8) auxiliary power outputs (unswitched); Fuses are rated @ 3.5A.; Filtered and electronically regulated outputs (built-in power supply).; ACM8 board main fuse is
FeaturesFire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.; a) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.; Alarm output relay indicates that FACP input is triggered (
SupervisionAC fail supervision (form "C" contacts).; Notification trigger is selectable for 30 seconds (factory set) or 6 hours.; Low battery and battery presence supervision (form "C" contact).
TemperatureOperating: 0ºC to 49ºC (32ºF to 120ºF).; Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).; Relative Humidity: 85% +/- 5%.; BTU/Hr. (approx.): 123 BTU/Hr.
Input optionsa) Eight (8) normally open (NO) inputs.; b) Eight (8) open collector inputs.; c) Any combination of the above.
Output optionsa) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
Output ratingsFuses are rated @ 3.5A.
Battery ChargingBuilt-in charger for sealed lead acid or gel type batteries.; Automatic switch over to stand-by battery when AC fails.; Zero voltage drop when unit switches over to battery backup (AC failure condition).; AC fail supervision (form "C" contact).; Battery fail and battery presence supervision (form "C
Visual IndicatorsRed LEDs indicate outputs are triggered (relays energized).; Green LED indicates FACP disconnect is triggered.; AC input and DC output LED indicators.
Power supply input optionsa) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).; b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maxi
Fire Alarm disconnect input optionsa) Normally open (NO) or normally closed (NC) dry contact input.; b) Polarity reversal input from FACP signaling circuit.

Where to buy

No retail prices for AL1024ULACM yet.Check retailers

Documents

Guides that use this part

No guides tag this part yet.Browse guides

Contractors certified on Altronix

Find Contractors who list a Altronix certification.Find Contractors

Q&A and reviews

Discussions 0 tagged

No discussions tagged to this part yet.

Start a discussion about this part